ATS22D47Q
meki upuštač–ATS22–upravljanje 220V-snaga 230V(11kW)/400...440V(22kW)
Glavno

Sakrij
range of product Altistart 22  
product or component type Soft starter  
product destination Asynchronous motors  
product specific application Pumps and fans  
component name ATS22  
network number of phases 3 phases  
[Us] rated supply voltage 230...440 V - 15...10 %  
motor power kW 11 kW 230 V
22 kW 400 V
22 kW 440 V
 
factory setting current 42 A  
power dissipation in W 48 W for standard applications  
utilisation category AC-53A  
type of start Start with torque control (current limited to 3.5 In)  
IcL starter rating 47 A connection in the motor supply line for standard applications  
IP degree of protection IP20  
 
Complementary

Sakrij
assembly style With heat sink  
function available Internal bypass  
supply voltage limits 195...484 V  
supply frequency 50...60 Hz - 10...10 %  
network frequency 45...66 Hz  
device connection In the motor supply line
To the motor delta terminals
 
[Uc] control circuit voltage 230 V -15...10 % 50/60 Hz  
control circuit consumption 20 W  
discrete output number 2  
discrete output type Relay outputs R1 230 V running, alarm, trip, stopped, not stopped, starting, ready C/O
Relay outputs R2 230 V running, alarm, trip, stopped, not stopped, starting, ready C/O
 
minimum switching current 100 mA 12 V DC relay outputs  
maximum switching current 5 A 250 V AC resistive 1 relay outputs
5 A 30 V DC resistive 1 relay outputs
2 A 250 V AC inductive 0.4 20 ms relay outputs
2 A 30 V DC inductive 7 ms relay outputs
 
discrete input number 3  
discrete input type Logic LI1, LI2, LI3 5 mA 4.3 kOhm  
discrete input voltage 24 V <= 30 V  
discrete input logic Positive logic LI1, LI2, LI3 < 5 V and <= 2 mA > 11 V >= 5 mA  
output current 0.4...1 Icl adjustable  
PTC probe input 750 Ohm  
communication port protocol Modbus  
connector type 1 RJ45  
communication data link Serial  
physical interface RS485 multidrop  
transmission rate 4800, 9600 or 19200 bps  
installed device 31  
protection type Thermal protection motor
Phase failure line
Thermal protection starter
 
marking CE  
type of cooling Forced convection  
operating position Vertical +/- 10 degree  
height 265 mm  
width 130 mm  
depth 169 mm  
product weight 7 kg  
power range 7...11 kW at 200...240 V 3 phases
15...25 kW at 380...440 V 3 phases
 
motor starter type Soft starter  
 
Environment

Sakrij
electromagnetic compatibility Conducted and radiated emissions level A IEC 60947-4-2
Damped oscillating waves level 3 IEC 61000-4-12
Electrostatic discharge level 3 IEC 61000-4-2
Immunity to electrical transients level 4 IEC 61000-4-4
Immunity to radiated radio-electrical interference level 3 IEC 61000-4-3
Voltage/current impulse level 3 IEC 61000-4-5
 
standards EN/IEC 60947-4-2  
product certifications CCC
CSA
C-Tick
GOST
UL
 
vibration resistance 1 gn 13...200 Hz EN/IEC 60068-2-6
1.5 mm 2...13 Hz EN/IEC 60068-2-6
 
shock resistance 15 gn 11 ms EN/IEC 60068-2-27  
noise level 45 dB  
pollution degree Level 2 IEC 60664-1  
relative humidity 0...95 % without condensation or dripping water EN/IEC 60068-2-3  
ambient air temperature for operation -10...40 °C without derating
> 40...< 60 °C with current derating 2.2 % per °C
 
ambient air temperature for storage -25...70 °C  
operating altitude <= 1000 m without derating
> 1000...< 2000 m with current derating of 2.2 % per additional 100 m
 
 
Offer Sustainability

Sakrij
Green Premium product Green Premium product  
Compliant - since 0938 - Schneider Electric declaration of conformity Compliant - since 0938 - Schneider Electric declaration of conformity  
Reference not containing SVHC above the threshold Reference not containing SVHC above the threshold  
Available Available PDF image  download Product environmental
Available Available PDF image  download End of life manual
 
Contractual warranty

Sakrij
Warranty period 18 months