ATV312H018M3

Main

[TAG[ hide ]]
range of product Altivar 312  
product or component type Variable speed drive  
product destination Asynchronous motors  
product specific application Simple machine  
assembly style With heat sink  
component name ATV312  
motor power kW 0.18 kW  
motor power hp 0.25 hp  
[Us] rated supply voltage 200...240 V (- 15...10 %)  
supply frequency 50...60 Hz (- 5...5 %)  
network number of phases 3 phases  
line current 1.9 A for 240 V
2.1 A for 200 V, 5 kA
 
EMC filter Without EMC filter  
apparent power 0.7 kVA  
maximum transient current 2.3 A for 60 s  
power dissipation in W 23 W at nominal load  
speed range 1...50  
asynchronous motor control profile Factory set : constant torque
Sensorless flux vector control with PWM type motor control signal
 
electrical connection Al1, Al2, Al3, AOV, AOC, R1A, R1B, R1C, R2A, R2B, LI1...LI6 terminal 2.5 mm² AWG 14
L1, L2, L3, U, V, W, PA, PB, PA/+, PC/- terminal 2.5 mm² AWG 14
 
supply Internal supply for logic inputs at 19...30 V, <= 100 mA for overload and short-circuit protection
Internal supply for reference potentiometer (2.2 to 10 kOhm) at 10...10.8 V, <= 10 mA for overload and short-circuit protection
 
communication port protocol CANopen
Modbus
 
IP degree of protection IP20 on upper part without cover plate
IP21 on connection terminals
IP31 on upper part
IP41 on upper part
 
option card CANopen daisy chain communication card
DeviceNet communication card
Fipio communication card
Modbus TCP communication card
Profibus DP communication card
 
 
Complementary

[TAG[ hide ]]
supply voltage limits 170...264 V  
network frequency 47.5...63 Hz  
prospective line Isc 5 kA  
continuous output current 1.5 A at 4 kHz  
output frequency 0...500 kHz  
nominal switching frequency 4 kHz  
switching frequency 2...16 kHz adjustable  
transient overtorque 170...200 % of nominal motor torque  
braking torque 100 % with braking resistor continuously
150 % without braking resistor
150 % with braking resistor for 60 s
 
regulation loop Frequency PI regulator  
motor slip compensation Adjustable
Automatic whatever the load
Suppressable
 
output voltage <= power supply voltage  
tightening torque 0.6 N.m Al1, Al2, Al3, AOV, AOC, R1A, R1B, R1C, R2A, R2B, LI1...LI6
0.8 N.m L1, L2, L3, U, V, W, PA, PB, PA/+, PC/-
 
insulation Electrical between power and control  
analogue input number 3  
analogue input type AI1 configurable voltage 0...10 V, input voltage 30 V max, impedance 30000 Ohm
AI2 configurable voltage +/- 10 V, input voltage 30 V max, impedance 30000 Ohm
AI3 configurable current 0...20 mA, impedance 250 Ohm
 
sampling duration AI1, AI2, AI3 8 ms for analog
LI1...LI6 4 ms for discrete
 
response time AOV, AOC 8 ms for analog
R1A, R1B, R1C, R2A, R2B 8 ms for discrete
 
linearity error +/- 0.2 % for output  
analogue output number 1  
analogue output type AOC configurable current 0...20 mA, impedance 800 Ohm, resolution 8 bits
AOV configurable voltage 0...10 V, impedance 470 Ohm, resolution 8 bits
 
discrete input logic (LI1...LI4) logic input not wired, < 13 V (state 1)
(LI1...LI6) negative logic (source), > 19 V (state 0)
(LI1...LI6) positive logic (source), < 5 V (state 0), > 11 V (state 1)
 
discrete output number 2  
discrete output type (R1A, R1B, R1C) configurable relay logic 1 NO + 1 NC, electrical durability 100000 cycles
(R2A, R2B) configurable relay logic NC, electrical durability 100000 cycles
 
minimum switching current R1-R2 10 mA at 5 V DC  
maximum switching current R1-R2 on inductive load, 2 A at 250 V AC, (cos phi = 0.4, and L/R = 7 ms)
R1-R2 on inductive load, 2 A at 30 V DC, (cos phi = 0.4, and L/R = 7 ms)
R1-R2 on resistive load, 5 A at 250 V AC, (cos phi = 1, and L/R = 0 ms)
R1-R2 on resistive load, 5 A at 30 V DC, (cos phi = 1, and L/R = 0 ms)
 
discrete input number 6  
discrete input type (LI1...LI6) programmable, 24 V 0...100 mA with PLC, impedance 3500 Ohm  
acceleration and deceleration ramps Linear adjustable separately from 0.1 to 999.9 s
S, U or customized
 
braking to standstill By DC injection  
protection type Input phase breaks drive
Line supply overvoltage and undervoltage safety circuits drive
Line supply phase loss safety function, for three phases supply drive
Motor phase breaks drive
Overcurrent between output phases and earth (on power up only) drive
Overheating protection drive
Short-circuit between motor phases drive
Thermal protection motor
 
insulation resistance >= 500 mOhm at 500 V DC for 1 minute  
local signalling 1 LED red for drive voltage
Four 7-segment display units for CANopen bus status
 
time constant 5 ms for reference change  
frequency resolution Analog input 0.1...100 Hz
Display unit 0.1 Hz
 
connector type 1 RJ45 Modbus/CANopen  
physical interface RS485 multidrop serial link  
transmission frame RTU  
transmission rate 10, 20, 50, 125, 250, 500 kbps or 1 Mbps CANopen
4800, 9600 or 19200 bps Modbus
 
number of addresses 1...247 Modbus
1...127 CANopen
 
number of drive 127 CANopen
31 Modbus
 
marking CE  
operating position Vertical +/- 10 degree  
height 145 mm  
width 72 mm  
depth 122 mm  
product weight 1.3 kg  
 
Environment

[TAG[ hide ]]
dielectric strength 2040 V DC between earth and power terminals
2880 V AC between control and power terminals
 
electromagnetic compatibility Electrical fast transient/burst immunity test conforming to IEC 61000-4-4 level 4
Electrostatic discharge immunity test conforming to IEC 61000-4-2 level 3
Radiated radio-frequency electromagnetic field immunity test conforming to IEC 61000-4-3 level 3
1.2/50 µs - 8/20 µs surge immunity test conforming to IEC 61000-4-5 level 3
 
standards IEC 61800-3
IEC 61800-5-1
 
product certifications CSA
C-Tick
DNV
GOST
NOM
UL
 
pollution degree 2  
protective treatment TC  
vibration resistance 1.5 mm (f = 3...13 Hz) conforming to EN/IEC 60068-2-6
1 gn (f = 13...150 Hz) conforming to EN/IEC 60068-2-6
 
shock resistance 15 gn for 11 ms conforming to EN/IEC 60068-2-27  
relative humidity 5...95 % without condensation conforming to IEC 60068-2-3
5...95 % without dripping water conforming to IEC 60068-2-3
 
ambient air temperature for storage -25...70 °C  
ambient air temperature for operation -10...50 °C without derating with protective cover on top of the drive
-10...60 °C with derating factor without protective cover on top of the drive
 
operating altitude <= 1000 m without derating
1000...3000 m with current derating 1 % per 100 m
 
 
Offer Sustainability

[TAG[ hide ]]
Green Premium product Green Premium product  
Compliant - since 0913 - Schneider Electric declaration of conformity Compliant - since 0913 - Schneider Electric declaration of conformity  
Reference not containing SVHC above the threshold Reference not containing SVHC above the threshold  
Available Available PDF image  download Product environmental
Available Available PDF image  download End of life manual