CAD32P7
TeSys D control relay - 3 NO + 2 NC - <= 690 V - 230 V AC standard coil
Main

Hide
range TeSys  
product name TeSys CAD  
product or component type Control relay  
device short name CAD  
contactor application Control circuit  
 
Complementary

Hide
utilisation category AC-14
AC-15
DC-13
 
pole contact composition 3 NO + 2 NC  
[Ue] rated operational voltage <= 690 V AC 25...400 Hz  
control circuit type AC 50/60 Hz  
[Uc] control circuit voltage 230 V AC 50/60 Hz  
[Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947  
[Ith] conventional free air thermal current 10 A at <= 60 °C  
Irms rated making capacity 140 A AC conforming to IEC 60947-5-1
250 A DC conforming to IEC 60947-5-1
 
[Icw] rated short-time withstand current 100 A 1 s
120 A 500 ms
140 A 100 ms
 
associated fuse rating 10 A gG conforming to IEC 60947-5-1  
[Ui] rated insulation voltage 690 V conforming to IEC 60947-5-1
600 V certifications UL
600 V certifications CSA
 
mounting support Plate
Rail
 
connections - terminals Screw clamp terminals 1 cable(s) 1...4 mm² - cable stiffness: flexible - without cable end
Screw clamp terminals 2 cable(s) 1...4 mm² - cable stiffness: flexible - without cable end
Screw clamp terminals 1 cable(s) 1...4 mm² - cable stiffness: flexible - with cable end
Screw clamp terminals 2 cable(s) 1...2.5 mm² - cable stiffness: flexible - with cable end
Screw clamp terminals 1 cable(s) 1...4 mm² - cable stiffness: solid - without cable end
Screw clamp terminals 2 cable(s) 1...4 mm² - cable stiffness: solid - without cable end
 
tightening torque 1.2 N.m - on screw clamp terminals - with screwdriver Philips No 2
1.2 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm
 
control circuit voltage limits 0.3...0.6 Uc drop-out
0.8...1.1 Uc operational 50 Hz
0.85...1.1 Uc operational 60 Hz
 
operating time 4...19 ms coil energisation and NC opening
12...22 ms coil energisation and NO closing
4...12 ms coil de-energisation and NO opening
6...17 ms coil de-energisation and NC closing
 
mechanical durability 30 Mcycles  
operating rate 180 cyc/mn  
inrush power in VA 70 VA at 20 °C 50 Hz  
hold-in power consumption in VA 8 VA at 20 °C 50 Hz  
minimum switching voltage 17 V  
minimum switching current 5 mA  
non-overlap time 1.5 ms on de-energisation (between NC and NO contact)
1.5 ms on energisation (between NC and NO contact)
 
insulation resistance > 10 MOhm  
mechanical robustness Shocks control relay open 10 Gn for 11 ms IEC 60068-2-27
Shocks control relay closed 15 Gn for 11 ms IEC 60068-2-27
Vibrations control relay open 2 Gn, 5...300 Hz IEC 60068-2-6
Vibrations control relay closed 4 Gn, 5...300 Hz IEC 60068-2-6
 
height 77 mm  
width 45 mm  
depth 84 mm  
product weight 0.58 kg  
 
Environment

Hide
standards VDE 0660
IEC 60947-5-1
NF C 63-140
BS 4794
EN 60947-5
 
product certifications CSA
UL
 
IP degree of protection IP2x front face conforming to VDE 0106  
protective treatment TH conforming to IEC 60068  
ambient air temperature for operation -40...70 °C  
ambient air temperature for storage -60...80 °C  
operating altitude 3000 m without derating  
 
Offer Sustainability

Hide
Sustainable offer status Green Premium product  
RoHS (date code: YYWW) Compliant - since 0627 - Schneider Electric declaration of conformity  
REACh Reference not containing SVHC above the threshold  
Product environmental profile Available PDF image  download Product environmental
Product end of life instructions Available PDF image  download End of life manual
 
Contractual warranty

Hide
Warranty period 18 months