Add to favorites
|
Help
Historic
XS4P12PC410
XS4P12PC410
inductive sensor XS4 M12 - L33mm - PPS - Sn4mm - 12..24VDC - cable 2m
Download your XS4P12PC410 datasheet
Change your selection
Discover other products & accessories
Discover your Schneider Electric tools
Characteristics
|
Dimensions Drawings
|
Mounting and Clearance
|
Connections and Schema
|
Performance Curves
|
Documents & Downloads
Main
Hide
range of product
OsiSense XS
series name
General purpose
sensor type
Inductive proximity sensor
device application
Mobile equipment
sensor name
XS4
sensor design
Cylindrical M12
size
33 mm
body type
Fixed
detector flush mounting acceptance
Non flush mountable
material
Plastic
type of output signal
Discrete
wiring technique
4-wire
[Sn] nominal sensing distance
4 mm
discrete output function
1 NO + 1 NC
output circuit type
DC
discrete output type
PNP
electrical connection
Cable
cable length
2 m
[Us] rated supply voltage
12...24 V DC with reverse polarity protection
switching capacity in mA
<= 200 mA with overload and short-circuit protection
IP degree of protection
IP68 double insulation conforming to IEC 60529
 
Complementary
Hide
safety level
SILCL 2 conforming to IEC 62061
PL = d conforming to EN/ISO 13849-1
SIL 2 conforming to EN/IEC 61508
safety reliability data
MTTFd = 1810 years
PFHd = 62.9E-9 1/h
SFF = 92 %
DC = 75 % with appropriate safety controller
service life
20 yr
thread type
M12 x 1
detection face
Frontal
front material
PPS
enclosure material
PPS
operating zone
0...3.2 mm
differential travel
1...15% of Sr
cable composition
4 x 0.22 mm²
wire insulation material
PvR
status LED
1 LED (yellow) for output state
supply voltage limits
10...36 V DC
switching frequency
<= 5000 Hz
voltage drop
<= 2 V (closed
current consumption
0...10 mA (no-load)
delay first up
<= 5 ms
delay response
<= 0.1 ms
delay recovery
<= 0.1 ms
marking
CE
threaded length
25 mm
height
12 mm
length
33 mm
product weight
0.07 kg
 
Environment
Hide
standards
EN/ISO 13849-1
IEC 62061
product certifications
CSA
TÜV
UL
E2
ambient air temperature for operation
-25...70 °C
ambient air temperature for storage
-40...85 °C
vibration resistance
25 gn, amplitude: +/- 2 mm (f = 10...55 Hz) conforming to IEC 60068-2-6
shock resistance
50 gn (duration = 11 ms) conforming to IEC 60068-2-27
 
Offer Sustainability
Hide
Sustainable offer status
Green Premium product
RoHS (date code: YYWW)
Compliant - since 0838 - Schneider Electric declaration of conformity
REACh
Reference not containing SVHC above the threshold
Product environmental profile
Available
download Product environmental
Product end of life instructions
Available
download End of life manual